Welcome to our website
  • head_banner_01

CJMM1 Series Moulded Case Circuit Breakers (MCCB)

Short Description:


Product Detail

Product Tags

Application

CJMM1 series moulded case circuit breaker(hereinafter referred to as circuit breaker) is pplicable for AC 50/60HZ power distribution network circuit with rated insulation voltage of 800V, rated operation voltage of 690V and rated operation current from 10A to 630A, it’s used to distribute power and prevent circuit and power supply equipment from damage due to overload, short circuit, under voltage and other faults, it’s also used for infrequent start of motor as well as overload, short circuit and under volt-age protection

This circuit breaker owns advantages of small volume, high breaking capacity, short arcing (or noarcing)etc, it can be equipped with access-ories like alarm contact, shunt release, auxiliary contact etc, it’s an ideal product for user.

The residual current circuit breaker can either be vertically installed (vertical installation) or be horizontally installed (horizontal installation)

The product is in accordance with the standards of IEC60947-2 and Gb140482

Product model

Note: There are four types of neutral pole (N pole) for four phases product.

The neutral pole of type A is not equipped with over-current tripping element, its always switched on, and it is not switched on or off together with other three poles.

The neutral pole of type B is not equipped with over-current tripping element, and it’s switched on or off together with other three poles(the neutral pole is switched on before being switched off)

The neutral pole of type C is equipped with over-current tripping element, and it’s switched on or off together with other three poles(the neutral pole is switched on before being switched off)

The neutral pole of type D is equipped with over-current tripping element, it’s always switched on and is not switched on or off together with other three poles.

Table 1

Accessory name Electronic release Compound release
Auxiliary contact,under voltage release,alam contact 287 378
Two auxiliary contact sets, alarm contact 268 368
Shunt release, alarm contact, auxiliary contact 238 348
Under voltage release, alarm contact 248 338
Auxiliary contact alarm contact 228 328
Shunt release alarm contact 218 318
Auxiliary contact under-voltage release 270 370
Two auxiliary contact sets 260 360
Shunt release under-voltage release 250 350
Shunt release auxiliary contact 240 340
Under-voltage release 230 330
Auxiliary contact 220 320
Shunt release 210 310
Alarm contact 208 308
No accessory 200 300
Classification

By breaking capacity: a standard type(type S) b higher breaking capacity type(type H)

By connection mode: a front board connection, b back board connection, c plugin type

By operation mode: a direct handle operation, b rotation handle opera-tion,c electrical operation

By number of poles: 2P, 3P, and 4P

By accessory: alarm contact, auxiliary contact, shunt release, under voltage release.

Normal Service Condition

 


  • Previous:
  • Next:

  • Write your message here and send it to us