Sticking to the principle of "Super Quality, Satisfactory service" ,We are striving to be a good business partner of you for Modular Contactor, 100ka Surge Protection Device, Mcb Main Circuit Breaker, We have extensive goods supply and the price is our advantage. Welcome to inquire about our products.
OEM High Quality Dry Contact Relay Exporter – Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical Detail:

product_icon

Instructions for use of relays

Rated working voltage: refers to the voltage required by the coil when the relay works normally, that is, the control voltage of the control circuit. Depending on the model of the relay, it can be either AC voltage or DC voltage.
DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter.
Pick-up current: refers to the minimum current that the relay can generate the pick-up action. In normal use, the given current must be slightly larger than the pull-in current, so that the relay can work stably. For the working voltage applied to the coil, generally do not exceed 1.5 times the rated working voltage, otherwise a large current will be generated and the coil will be burned.
Release current: It refers to the maximum current that the relay produces to release the action. When the current in the pull-in state of the relay is reduced to a certain extent, the relay will return to the unenergized release state. The current at this time is much smaller than the pull-in current.
Contact switching voltage and current: refers to the voltage and current that the relay is allowed to load. It determines the magnitude of the voltage and current that the relay can control. It cannot exceed this value when using it, otherwise it is easy to damage the contacts of the relay.

product_icon

Application

Used in switchgear, air conditioning units, elevator machine room, pumps, fans and other motor control applications. With phase loss, overload protection.

product_icon

Features

Built-in microprocessor, current measurement accuracy≤ 2%. Konb setting, LED indicator shows working status. With phase failure, overload, unbalance, stall protection, four optional trip classes. No-load start, protection of any phase loss or overload. NO contact protection.

product_icon

Technical Data

Rated control supply voltage AC38 0V, >AC2 20V 50Hz/60Hz
Curr ent measurement accuracy 52%
Setting accuracy 55%
Setti ng mode Knob setting
Num ber of poles 3P
Rated insulation voltage AC690V
Class of pollution 3
IP Class IP20
Contact capacity Ith:SA; AC-15 : Ue/Ie 380V/0.95A 240V/1.5A
Use category AC-15
Elect rical life 10′
Mechanical life 106
Altitude 52000m
Allowable relative humility 550%/40°(condensation)
Power consumption ≤1.5VA
Installation /Screw or DIN rail mounting

product_icon

Wiring Diagram

details (1)
product_icon

Dimensions

details (2)
product_icon

factory

factory
factory
factory
factory
factory
factory
factory
factory
product_icon

certification

certification
certification
certification
certification
certification
certification
certification
certification


Product detail pictures:

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures

OEM High Quality Dry Contact Relay Exporter –  Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical detail pictures


Related Product Guide:

The corporation upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will proceed to provide aged and new buyers from home and abroad whole-heatedly for OEM High Quality Dry Contact Relay Exporter – Built-in microprocessor, current measurement accuracy ≤2%. No-load start, protection of any phase failure or overload. NO contact protection – Sofielec Electrical , The product will supply to all over the world, such as: Jamaica, Maldives, Colombia, We also have the strong ability of integration to supply our best service, and plan to build the warehouse in the different countries around the world, that will probably be more conveniently to service our customers.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Alan from Georgia - 2018.11.11 19:52
    We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By trameka milhouse from Nigeria - 2017.09.16 13:44
    Write your message here and send it to us